Deploying the Aria Suite Lifecycle using VCF 5

The official documentation for deploying the Aria Suite can be found here

First step is to download the bundle by going to sddc-manager -> Repository -> Bundle management. Look for VMware Software Install Bundle – vRealize Suite Lifecycle Manager 8.16.0-23377566

After the download is complete we can go to Administration -> VMware Aria Suite and a deploy button should be available. If the deploy button is not available due to X-Region Application Virtual Network is not created error please follow the instructions found here:

Verify the Prerequisites and click on begin

Verify the network settings and click Next

Fill up the network and appliance settings and click next

Review the summary and click Finish

We can follow the progress by click on the Task on the bottom of the screen

This allows me to see the subtasks that are running

Once the deployment is complete we can open the Aria Suite Lifecycle by clicking on the Window icon link

Additionally towards the bottom of the page we can see the rest of the Aria Suite components that can be deployed.

We can then log in to the Aria Suite Lifecycle using vcfadmin@local with the credentials used during the deployment.

We can see that the deployment wizard also created a few configurations items.

We can now proceed with the deployment of the rest of the components. The deployments will be done from Aria Suite Lifecycle.

Properly cleaning up VCF bundles

With all the recent releases for VCF i noticed that my file system was getting full and once the updates are complete i wanted to reclaim all that used space.

The first step was to identify the Bundle ID. We can find this by going to the bundle itself and checking out the details by clicking on View Details

For example this specific Bundle ID is 86da0038-b68d-4368-8be1-576568a68c54

At this point i had to log in to the sddc manager and issue the following command:

/opt/vmware/vcf/lcm/lcm-app/bin/bundle_cleanup.py 86da0038-b68d-4368-8be1-576568a68c54

We can also specify multiple bundle IDs:

/opt/vmware/vcf/lcm/lcm-app/bin/bundle_cleanup.py 96368be7-554c-40d1-81ef-3ad0b47c16f0 7d5af5d8-0f01-4fc5-b22b-c805f5cd00fb cf4ab52f-b999-4f6a-8c29-2db829110925

I hope this helps

Upgrading VCF 5.x to VCF 5.1.1 Step by Step

With the release of of VCF 5.1.1 I wanted to get my lab upgraded. The release blog can be found here and the release notes are here

Please note that some of the components within the VCF will still need additional upgrading. Please read the release notes for additional details.

We can start by going to Inventory -> Workload Domains -> Select the domain -> Update/Patches -> Select the VCF version -> Download now. If you do not see the newest releases go to Administration -> Online Depot and add a VMware Customer Connect account that has access to perform downloads.

The next step is to upgrade VCF by going to Inventory -> Workload Domains -> Select the workload domain -> Update/Patches -> Select the cloud foundation version we’re upgrading to and click on Update Now for the VMware Cloud Foundation Update 5.1.1

Next we are taken to the Upgrade page where we can follow the upgrade for each one of the components

Once the upgrade is complete we can click Finish to be returned back to the main screen

Because we are changing the SDDC-Manager versions i would strongly recommend to clear cache and log back in before going forward.

Next step is to upgrade NSX-T installation to NSX-T 4.1.2.3. The release notes can be found here.

We can also download it directly from the workload domain by going to Inventory -> Workload Domains -> Select the domain -> Update/Patches -> Download now

Once the download is complete we can proceed with updating the NSX components by clicking on the update now

Make the proper selection and click next

Make the proper selection and click next

Make the proper selection and click next

Review the options and click on Finish

The upgrade will go thought upgrading the NSX edges. We can view the upgrade status by clicking on view status

Once the upgrade is complete we can proceed with the vCenter Upgrade. VCF 5.1.1 comes with vCenter Server 8.0 Updated 2b. The release notes can be found here. We can go to Inventory -> Workload Domains -> Select the workload domain -> Update/Patches -> Under Available updates click on Download now.

Once the download is complete we can click on Update now

Confirm that we have a backup

We can follow the status of the upgrade by clicking on the view status tab

Here we can see the different components that are getting upgraded

Once the upgrade is complete we are taken back to the previous page where we can see that the ESXi servers are next. The release notes can be found here. Click on Download Now.

Once the download is complete we can click on Update now

If we have multiple clusters we can enable Cluster-level selection and select the specific cluster(s) we want to upgrade.

We can also enable sequential cluster upgrade, quick boot and the ability to evacuate offline VMs part of the maintenance. Click Next

We get to review the options once again before we click finish to to submit the task

Once submitted we can view the status by clicking on View Status

And with that we are finished with the workload domain. We can follow the same steps for the other domains

Don’t forget to clean up the download bundles by following the steps from my other blog here

VCF depot build numbers

Bundle	Product Version	Size	Bundle	Component	Bundle Type
bundle-111778	5.1.1.0	605.7	ESX_HOST-8.0.2-23305546	PATCH	
bundle-111779	5.1.1.0	11381.3	NSX_T_MANAGER-4.1.2.3.0-23382408	PATCH	
bundle-111777	5.1.1.0	0	SDDC_MANAGER_VCF-5.1.1.0-23480823	PATCH	(Drift)
bundle-111776	5.1.1.0	2331.6	SDDC_MANAGER_VCF-5.1.1.0-23480823	PATCH	
bundle-111781	5.1.1.0	17064.2	VCENTER-8.0.2.00200-23319993	PATCH	
bundle-111780	5.1.1.0	14664.6	NSX_T_MANAGER-4.1.2.3.0-23382408	INSTALL	
bundle-111782	5.1.1.0	10742.4	VCENTER-8.0.2.00200-23319993	INSTALL	
bundle-110346	5.1.1.0	1847.9	VRSLCM-8.16.0-23377566	INSTALL	
bundle-99536	5.1.0.0	640	ESX_HOST-8.0.2-22380479	PATCH	
bundle-99541	5.1.0.0	10500.4	NSX_T_MANAGER-4.1.2.1.0-22667789	PATCH	
bundle-99539	5.1.0.0	2089.2	SDDC_MANAGER_VCF-5.1.0.0-22688368	PATCH	
bundle-99540	5.1.0.0	0	SDDC_MANAGER_VCF-5.1.0.0-22688368	PATCH	(Drift)
bundle-99537	5.1.0.0	16801.6	VCENTER-8.0.2.00100-22617221	PATCH	
bundle-99542	5.1.0.0	14606.2	NSX_T_MANAGER-4.1.2.1.0-22667789	INSTALL	
bundle-99538	5.1.0.0	10493	VCENTER-8.0.2.00100-22617221	INSTALL	
bundle-98366	5.1.0.0	1817.8	VRSLCM-8.14.0-22630472	INSTALL	
bundle-94375	5.0.0.1	2044.9	SDDC_MANAGER_VCF-5.0.0.1-22485660	PATCH	
bundle-94376	5.0.0.1	251.5	SDDC_MANAGER_VCF-5.0.0.1-22485660	PATCH	(Drift)
bundle-80035	5.0.0.0	599.5	ESX_HOST-8.0.1-21813344	PATCH	
bundle-80031	5.0.0.0	10089.9	NSX_T_MANAGER-4.1.0.2.0-21761691	PATCH	
bundle-80030	5.0.0.0	251.3	SDDC_MANAGER_VCF-5.0.0.0-21822418	PATCH	(Drift)
bundle-80029	5.0.0.0	2044.7	SDDC_MANAGER_VCF-5.0.0.0-21822418	PATCH	
bundle-80033	5.0.0.0	9867.6	VCENTER-8.0.1.00100-21815093	PATCH	
bundle-80032	5.0.0.0	13874.6	NSX_T_MANAGER-4.1.0.2.0-21761691	INSTALL	
bundle-80034	5.0.0.0	9867.6	VCENTER-8.0.1.00100-21815093	INSTALL	
bundle-79587	5.0.0.0	1091.8	VRSLCM-8.10.0-21331275	INSTALL	
bundle-83610	4.5.2.0	382.1	ESX_HOST-7.0.3-21930508	PATCH	
bundle-87318	4.5.2.0	8615.4	NSX_T_MANAGER-3.2.3.1.0-22104592	PATCH	
bundle-88445	4.5.2.0	2012.6	SDDC_MANAGER_VCF-4.5.2.0-22223457	PATCH	
bundle-88446	4.5.2.0	250.5	SDDC_MANAGER_VCF-4.5.2.0-22223457	PATCH	(Drift)
bundle-81146	4.5.2.0	6420	VCENTER-7.0.3.01500-21784236	PATCH	
bundle-87319	4.5.2.0	10618.2	NSX_T_MANAGER-3.2.3.1.0-22104592	INSTALL	
bundle-81147	4.5.2.0	8575.4	VCENTER-7.0.3.01500-21784236	INSTALL	
bundle-84015	4.5.2.0	1091.3	VRSLCM-8.10.0-21950667	INSTALL	
bundle-73789	4.5.1.0	381.8	ESX_HOST-7.0.3-21424296	PATCH	
bundle-73785	4.5.1.0	8402.7	NSX_T_MANAGER-3.2.2.1.0-21487560	PATCH	
bundle-77261	4.5.1.0	2150	SDDC_MANAGER_VCF-4.5.1.0-21682411	PATCH	
bundle-77262	4.5.1.0	250.2	SDDC_MANAGER_VCF-4.5.1.0-21682411	PATCH	(Drift)
bundle-73787	4.5.1.0	6419.8	VCENTER-7.0.3.01400-21477706	PATCH	
bundle-73786	4.5.1.0	10461.8	NSX_T_MANAGER-3.2.2.1.0-21487560	INSTALL	
bundle-73788	4.5.1.0	8575.1	VCENTER-7.0.3.01400-21477706	INSTALL	
bundle-61598	4.5.0.0	382.9	ESX_HOST-7.0.3-20328353	PATCH	
bundle-62768	4.5.0.0	8064	NSX_T_MANAGER-3.2.1.2.0-20541212	PATCH	
bundle-63600	4.5.0.0	247.6	SDDC_MANAGER_VCF-4.5.0.0-20612863	PATCH	(Drift)
bundle-63599	4.5.0.0	2106	SDDC_MANAGER_VCF-4.5.0.0-20612863	PATCH	
bundle-61594	4.5.0.0	6381.1	VCENTER-7.0.3.01000-20395099	PATCH	
bundle-62769	4.5.0.0	10053.7	NSX_T_MANAGER-3.2.1.2.0-20541212	INSTALL	
bundle-61596	4.5.0.0	8344.2	VCENTER-7.0.3.01000-20395099	INSTALL	
bundle-62801	4.5.0.0	1085.4	VRSLCM-8.8.2-20080494	INSTALL	
bundle-58347	4.4.1.1	10246.1	SDDC_MANAGER_VCF-4.4.1.1-19948546	PATCH	
bundle-58348	4.4.1.1	233.8	SDDC_MANAGER_VCF-4.4.1.1-19948546	PATCH	(Drift)
bundle-56937	4.4.1.0	395.5	ESX_HOST-7.0.3-19482537	PATCH	
bundle-57347	4.4.1.0	7127.2	NSX_T_MANAGER-3.1.3.7.4-19762317	PATCH	
bundle-57344	4.4.1.0	10246.2	SDDC_MANAGER_VCF-4.4.1.0-19766960	PATCH	
bundle-57346	4.4.1.0	233.8	SDDC_MANAGER_VCF-4.4.1.0-19766960	PATCH	(Drift)
bundle-55743	4.4.1.0	7139	VCENTER-7.0.3.00500-19480866	PATCH	
bundle-57348	4.4.1.0	8535.7	NSX_T_MANAGER-3.1.3.7.4-19762317	INSTALL	
bundle-55745	4.4.1.0	9202.7	VCENTER-7.0.3.00500-19480866	INSTALL	
bundle-52995	4.4.0.0	395.3	ESX_HOST-7.0.3-19193900	PATCH	
bundle-52980	4.4.0.0	7154.5	NSX_T_MANAGER-3.1.3.5.0-19068434	PATCH	
bundle-56535	4.4.0.0	230.4	SDDC_MANAGER_VCF-4.4.0.0-19617653	PATCH	(Drift)
bundle-53432	4.4.0.0	230.3	SDDC_MANAGER_VCF-4.4.0.0-19312029	PATCH	(Drift)
bundle-53431	4.4.0.0	10188.6	SDDC_MANAGER_VCF-4.4.0.0-19312029	PATCH	
bundle-52986	4.4.0.0	7223.8	VCENTER-7.0.3.00300-19234570	PATCH	
bundle-52611	4.4.0.0	905.6	VRSLCM-8.6.2-19221620	PATCH	
bundle-52982	4.4.0.0	8610	NSX_T_MANAGER-3.1.3.5.0-19068434	INSTALL	
bundle-52990	4.4.0.0	9244.9	VCENTER-7.0.3.00300-19234570	INSTALL	
bundle-52610	4.4.0.0	1111.3	VRSLCM-8.6.2-19221620	INSTALL	
bundle-52704	4.3.1.1	10695.5	SDDC_MANAGER_VCF-4.3.1.1-19235535	PATCH	
bundle-52705	4.3.1.1	230.5	SDDC_MANAGER_VCF-4.3.1.1-19235535	PATCH	(Drift)
bundle-47505	4.3.1.0	389.4	ESX_HOST-7.0.2-18426014	PATCH	
bundle-47501	4.3.1.0	7105.9	NSX_T_MANAGER-3.1.3.1.0-18504668	PATCH	
bundle-48392	4.3.1.0	230.5	SDDC_MANAGER_VCF-4.3.1.0-18624509	PATCH	(Drift)
bundle-48390	4.3.1.0	10336.5	SDDC_MANAGER_VCF-4.3.1.0-18624509	PATCH	
bundle-47503	4.3.1.0	5394	VCENTER-7.0.2.00500-18455184	PATCH	
bundle-47700	4.3.1.0	6207.1	VRA-8.5.0-18472703	PATCH	
bundle-47696	4.3.1.0	759.9	VRLI-8.4.1-18136317	PATCH	
bundle-47698	4.3.1.0	3141.6	VROPS-8.5.0-18255622	PATCH	
bundle-47703	4.3.1.0	847.8	VRSLCM-8.4.1-18537943	PATCH	
bundle-47502	4.3.1.0	8501.4	NSX_T_MANAGER-3.1.3.1.0-18504668	INSTALL	
bundle-47504	4.3.1.0	7383.3	VCENTER-7.0.2.00500-18455184	INSTALL	
bundle-47701	4.3.1.0	6632.3	VRA-8.5.0-18472703	INSTALL	
bundle-47695	4.3.1.0	1414.8	VRLI-8.4.1-18136317	INSTALL	
bundle-47697	4.3.1.0	2563.3	VROPS-8.5.0-18255622	INSTALL	
bundle-47702	4.3.1.0	1037.1	VRSLCM-8.4.1-18537943	INSTALL	
bundle-43745	4.3.0.0	390.1	ESX_HOST-7.0.2-17867351	PATCH	
bundle-46466	4.3.0.0	7123.1	NSX_T_MANAGER-3.1.3.0.0-18328989	PATCH	
bundle-47006	4.3.0.0	10331.2	SDDC_MANAGER_VCF-4.3.0.0-18433963	PATCH	
bundle-47008	4.3.0.0	230.3	SDDC_MANAGER_VCF-4.3.0.0-18433963	PATCH	(Drift)
bundle-46468	4.3.0.0	5394.4	VCENTER-7.0.2.00400-18356314	PATCH	
bundle-40064	4.3.0.0	6360.7	VRA-8.4.1-18054500	PATCH	
bundle-43778	4.3.0.0	742.7	VRLI-8.4.0-17828109	PATCH	
bundle-39857	4.3.0.0	2191.3	VROPS-8.4.0-17863947	PATCH	
bundle-40066	4.3.0.0	841.3	VRSLCM-8.4.1-18067607	PATCH	
bundle-40908	4.3.0.0	3478.7	WSA-3.3.5-18049997	PATCH	
bundle-46467	4.3.0.0	8568.5	NSX_T_MANAGER-3.1.3.0.0-18328989	INSTALL	
bundle-46469	4.3.0.0	7383.7	VCENTER-7.0.2.00400-18356314	INSTALL	
bundle-40080	4.3.0.0	6773.8	VRA-8.4.1-18054500	INSTALL	
bundle-43777	4.3.0.0	1414.2	VRLI-8.4.0-17828109	INSTALL	
bundle-43774	4.3.0.0	2538.2	VROPS-8.4.0-17863947	INSTALL	
bundle-40906	4.3.0.0	1032.7	VRSLCM-8.4.1-18067607	INSTALL	
bundle-40907	4.3.0.0	4180.7	WSA-3.3.5-18049997	INSTALL	
bundle-42515	4.2.1.0	6995.1	NSX_T_MANAGER-3.1.2.0.0-17883596	PATCH	
bundle-42906	4.2.1.0	209.3	SDDC_MANAGER_VCF-4.2.1.0-18016307	PATCH	(Drift)
bundle-42905	4.2.1.0	10142.7	SDDC_MANAGER_VCF-4.2.1.0-18016307	PATCH	
bundle-42521	4.2.1.0	5114.4	VCENTER-7.0.1.00301-17956102	PATCH	
bundle-42519	4.2.1.0	8394.9	NSX_T_MANAGER-3.1.2.0.0-17883596	INSTALL	
bundle-42522	4.2.1.0	7722.8	VCENTER-7.0.1.00301-17956102	INSTALL	
bundle-37983	4.2.0.0	369	ESX_HOST-7.0.1-17551050	PATCH	
bundle-32810	4.2.0.0	7057.7	NSX_T_MANAGER-3.1.0.0.0-17107167	PATCH	
bundle-37979	4.2.0.0	10070	SDDC_MANAGER_VCF-4.2.0.0-17559673	PATCH	
bundle-37982	4.2.0.0	209.3	SDDC_MANAGER_VCF-4.2.0.0-17559673	PATCH	(Drift)
bundle-35321	4.2.0.0	5140.8	VCENTER-7.0.1.00200-17327517	PATCH	
bundle-31385	4.2.0.0	5706	VRA-8.2.0-17018654	PATCH	
bundle-31221	4.2.0.0	687.3	VRLI-8.2.0-16957702	PATCH	
bundle-31219	4.2.0.0	2560.1	VROPS-8.2.0-16949153	PATCH	
bundle-32076	4.2.0.0	947	VRSLCM-8.2.0-17513665	PATCH	
bundle-32079	4.2.0.0	3286.2	WSA-3.3.4-17498518	PATCH	
bundle-32811	4.2.0.0	8427.7	NSX_T_MANAGER-3.1.0.0.0-17107167	INSTALL	
bundle-35322	4.2.0.0	7749.3	VCENTER-7.0.1.00200-17327517	INSTALL	
bundle-30921	4.2.0.0	6515.4	VRA-8.2.0-16980951	INSTALL	
bundle-32927	4.2.0.0	1325.1	VRLI-8.2.0-16957702	INSTALL	
bundle-30919	4.2.0.0	2861.4	VROPS-8.2.0-16949153	INSTALL	
bundle-32074	4.2.0.0	1138.9	VRSLCM-8.2.0-17513665	INSTALL	
bundle-32078	4.2.0.0	4115.3	WSA-3.3.4-17498518	INSTALL	
bundle-33257	4.1.0.1	343.9	ESX_HOST-7.0.1-17168206	PATCH	
bundle-33416	4.1.0.1	9787.6	SDDC_MANAGER_VCF-4.1.0.1-17206953	PATCH	
bundle-52820	4.1.0.1	1132.9	SDDC_MANAGER_VCF-4.1.0.1-17206953	PATCH	(Drift)
					

How to use: Downloading specific VCF bundles via CLI

Downloading specific VCF bundles via CLI

I wanted to reuse my VCF downloaded bundles on another SDDC Manager system so that i wont have to download it from internet again. I found an easy guide here in the VMware documentation. My goal was to download the specific bundle once and upload it on other SDDC Managers.

The first command from SDDC manager was to list the bundles. The lcm bundle transfer utility can be found in /opt/vmware/vcf/lcm/lcm-tools/bin

./lcm-bundle-transfer-util -du ${depotUser} -l -p ${product_version}

I replaced the ${depotUser} with my vmware email address and ${product_version} with the version of the VCF product i wanted to install in my case 5.0.0.0. I was greeted with a list of bundle IDs and the specific component that it was for:

Enter Myvmware user password:
Validating the depot user credentials...

Bundle         Product  Bundle Size  Components
               Version  (in MB)
bundle-80035   5.0.0.0  599.5 MB     ESX_HOST-8.0.1-21813344
bundle-80031   5.0.0.0  10089.9 MB   NSX_T_MANAGER-4.1.0.2.0-21761691
bundle-80029   5.0.0.0  2044.7 MB    SDDC_MANAGER_VCF-5.0.0.0-21822418
bundle-80030   5.0.0.0  251.3 MB     SDDC_MANAGER_VCF-5.0.0.0-21822418
bundle-80033   5.0.0.0  9867.6 MB    VCENTER-8.0.1.00100-21815093

In my case i need the installer. To download a specific bundle we run

./lcm-bundle-transfer-util --download --outputDirectory ${absolute-path-output-dir} --depotUser ${depotUser} -b ${bundle_name}

in my case it was:

./lcm-bundle-transfer-util --download --outputDirectory /some/temporary/location --depotUser [email protected] -b bundle-80029

This allowed me to grab the download from /some/temporary/path and save it/upload it on my other SDDC Managers that were missing it.

Finally before the patch can be used in SDDC Manager we need to upload it to the repo. Please note that once we issue the upload command the download gets deleted, so make sure you save the download ahead of time

./lcm-bundle-transfer-util --upload --bundleDirectory /some/temporary/path -b bundle-80029

or via API

curl -k http://127.0.0.1/lcm/bundle/upload -X POST -d ‘{“bundle”:”/some/temporary/path/bundle-80029.tar”,”manifest”:”/some/temporary/path/bundle-80029.manifest”, “signature”:”/some/temporary/path/bundle-80029.manifest.sig”}’ -H ‘Content-Type:application/json’

Once the upload was complete i was able to see it in SDDC Manager as a package that i can apply.

A list of bundles can be found here

VCF depot build numbers

VCF VersionBundle NameSizeComponentTypeBundle ID
5.1.0.0bundle-99536640.0MBESX_HOST-8.0.2-22380479PATCHefca585c-4fd8-4ec4-9b08-c50701aa2f7d
bundle-9954110500.4MBNSX_T_MANAGER-4.1.2.1.0-22667789PATCH39759b15-d985-4c15-85d6-7d44fd24df45
bundle-995392089.2MBSDDC_MANAGER_VCF-5.1.0.0-22688368PATCHb9308692-c98a-4afc-b49f-601f16105d92
bundle-995400.0MBSDDC_MANAGER_VCF-5.1.0.0-22688368PATCH(Drift)f3a11b49-4209-4c2b-8b26-aea98b1f8450
bundle-9953716801.6MBVCENTER-8.0.2.00100-22617221PATCH0a1ba239-eab9-41c6-b0e6-9738a463bdbe
bundle-9954214606.2MBNSX_T_MANAGER-4.1.2.1.0-22667789INSTALLc5a39cf5-eca2-4206-8375-082f827612b8
bundle-9953810493.0MBVCENTER-8.0.2.00100-22617221INSTALL96cf61e1-85b3-461f-8dfe-5abbeed33ab7
5.0.0.1bundle-943752044.9MBSDDC_MANAGER_VCF-5.0.0.1-22485660PATCH8fe51a93-ff6b-45e1-b9b9-49ad60612703
bundle-94376251.5MBSDDC_MANAGER_VCF-5.0.0.1-22485660PATCH(Drift)0602cf8f-9a37-4b38-90ba-f26a19a80cf6
5.0.0.0bundle-80035599.5MBESX_HOST-8.0.1-21813344PATCHef970211-02bf-429a-8edd-91f3bc7c1b42
bundle-8003110089.9MBNSX_T_MANAGER-4.1.0.2.0-21761691PATCH3ae76665-4c93-422e-9af8-aafe79a1ee7f
bundle-800292044.7MBSDDC_MANAGER_VCF-5.0.0.0-21822418PATCHb562189e-0c93-489e-a0b9-e12b01efffb8
bundle-80030251.3MBSDDC_MANAGER_VCF-5.0.0.0-21822418PATCH(Drift)393fb05f-23ff-47d1-8b84-db39647677ce
bundle-800339867.6MBVCENTER-8.0.1.00100-21815093PATCHb862f68d-22a8-457d-a85d-56d72370076e
bundle-8003213874.6MBNSX_T_MANAGER-4.1.0.2.0-21761691INSTALL7df70351-902f-49e4-a366-553f340d2f3a
bundle-800349867.6MBVCENTER-8.0.1.00100-21815093INSTALLb1f5bf8e-c133-44a3-9393-efa772c9c0ce
4.5.2.0bundle-83610382.1MBESX_HOST-7.0.3-21930508PATCHb9462fde-a7d0-4965-b217-cd09bd21bcc5
bundle-873188615.4MBNSX_T_MANAGER-3.2.3.1.0-22104592PATCH259b722b-f8b5-4b4c-9e71-4ebe135cd38e
bundle-884452012.6MBSDDC_MANAGER_VCF-4.5.2.0-22223457PATCH363bd141-7d19-4287-9c7a-091c11042ca0
bundle-88446250.5MBSDDC_MANAGER_VCF-4.5.2.0-22223457PATCH(Drift)85192dee-1d47-4211-bbdb-999d604f601f
bundle-811466420.0MBVCENTER-7.0.3.01500-21784236PATCH4ac2b679-5e5b-43a6-b74b-5fd4e3c978c0
bundle-8731910618.2MBNSX_T_MANAGER-3.2.3.1.0-22104592INSTALLfcde592c-7a6c-4c92-a6b3-669833dc6910
bundle-811478575.4MBVCENTER-7.0.3.01500-21784236INSTALL659351d3-9d66-45d6-84b0-14451f54cd6f
4.5.1.0bundle-73789381.8MBESX_HOST-7.0.3-21424296PATCH2b458531-b783-458e-bc43-3da1ddcd096f
bundle-737858402.7MBNSX_T_MANAGER-3.2.2.1.0-21487560PATCHe5f9e44f-9123-425e-bee9-07806379d671
bundle-772612150.0MBSDDC_MANAGER_VCF-4.5.1.0-21682411PATCH65b6d750-5ef3-4456-b4c2-65ef96048fb6
bundle-77262250.2MBSDDC_MANAGER_VCF-4.5.1.0-21682411PATCH(Drift)8a132cc7-f9b7-4f69-b654-7ea8f7059905
bundle-737876419.8MBVCENTER-7.0.3.01400-21477706PATCH3b8ae94b-582b-4356-b152-2b01e947a072
bundle-7378610461.8MBNSX_T_MANAGER-3.2.2.1.0-21487560INSTALLf90627d1-a038-4771-9a8a-dfbe1ffa760b
bundle-737888575.1MBVCENTER-7.0.3.01400-21477706INSTALL37ec3570-d827-4f32-8eac-92e2b6e21964
4.5.0.0bundle-61598382.9MBESX_HOST-7.0.3-20328353PATCHc6a50311-47be-4b53-891d-9f5ecb75d087
bundle-627688064.0MBNSX_T_MANAGER-3.2.1.2.0-20541212PATCH4f2f5d65-53ca-4b58-a85c-49d5b337cc64
bundle-635992106.0MBSDDC_MANAGER_VCF-4.5.0.0-20612863PATCHb984c5e4-167a-4886-8f23-be34c9176ca9
bundle-63600247.6MBSDDC_MANAGER_VCF-4.5.0.0-20612863PATCH(Drift)4581e5e3-b82f-46b9-99cc-e35584f14de0
bundle-615946381.1MBVCENTER-7.0.3.01000-20395099PATCH34b75350-c552-4c93-b306-75658a3332a4
bundle-6276910053.7MBNSX_T_MANAGER-3.2.1.2.0-20541212INSTALL4fe5a96f-d5c3-4730-9970-6d94bc5a63af
bundle-615968344.2MBVCENTER-7.0.3.01000-20395099INSTALL8da5d209-c8ac-493f-9e6a-f00a5bd5f155
4.4.1.1bundle-5834710246.1MBSDDC_MANAGER_VCF-4.4.1.1-19948546PATCH193486eb-53f5-40c7-8012-b5dcab515ebf
bundle-58348233.8MBSDDC_MANAGER_VCF-4.4.1.1-19948546PATCH(Drift)3c32c5d6-b5e0-49c6-9a86-90bcd3de671e
4.4.1.0bundle-56937395.5MBESX_HOST-7.0.3-19482537PATCH043e2b99-b36f-45b9-a4a2-1632a24764ef
bundle-573477127.2MBNSX_T_MANAGER-3.1.3.7.4-19762317PATCH193486eb-53f5-40c7-8012-b5dcab515ebf
bundle-5734410246.2MBSDDC_MANAGER_VCF-4.4.1.0-19766960PATCH13d87a53-298d-4ee5-98ca-b9e10eece7a5
bundle-57346233.8MBSDDC_MANAGER_VCF-4.4.1.0-19766960PATCH(Drift)8c178f33-b28d-47d0-88da-aa94f309a042
bundle-557437139.0MBVCENTER-7.0.3.00500-19480866PATCH05be2afd-990d-45bd-9472-fab032e8c696
bundle-573488535.7MBNSX_T_MANAGER-3.1.3.7.4-19762317INSTALL3c32c5d6-b5e0-49c6-9a86-90bcd3de671e
bundle-557459202.7MBVCENTER-7.0.3.00500-19480866INSTALL4073e1c9-4eeb-4d46-97b5-374daa24be41
4.4.0.0bundle-52995395.3MBESX_HOST-7.0.3-19193900PATCHd214e445-8509-4d50-adac-59d56acd86ae
bundle-529807154.5MBNSX_T_MANAGER-3.1.3.5.0-19068434PATCH348187d2-9930-41d6-9ee1-345857e53a3f
bundle-5343110188.6MBSDDC_MANAGER_VCF-4.4.0.0-19312029PATCH4f22c22f-441d-4ed9-bb70-697d10bcf028
bundle-53432230.3MBSDDC_MANAGER_VCF-4.4.0.0-19312029PATCH(Drift)54485cb4-8db2-4e86-8962-5c4fc54d5727
bundle-56535230.4MBSDDC_MANAGER_VCF-4.4.0.0-19617653PATCH(Drift)b27c6275-742c-4d51-a907-eba0e158ede3
bundle-529867223.8MBVCENTER-7.0.3.00300-19234570PATCH3bbd1018-1e3f-478d-b201-4287aeb136d8
bundle-529828610.0MBNSX_T_MANAGER-3.1.3.5.0-19068434INSTALL7ae68403-5863-4fcf-8886-f27460c59e85
bundle-529909244.9MBVCENTER-7.0.3.00300-19234570INSTALL7b7816d6-64f9-42a1-be35-3c5d185f08a3
4.3.1.1bundle-5270410695.5MBSDDC_MANAGER_VCF-4.3.1.1-19235535PATCH4ea809be-5359-4ac8-b32f-2337c0820d8b
bundle-52705230.5MBSDDC_MANAGER_VCF-4.3.1.1-19235535PATCH(Drift)fd85a861-a972-4da8-b708-8b35aa897e25
4.3.1.0bundle-47505389.4MBESX_HOST-7.0.2-18426014PATCH50f69840-b920-4d1b-81fa-bb934fa13c24
bundle-475017105.9MBNSX_T_MANAGER-3.1.3.1.0-18504668PATCH2f39eed1-94e3-4295-937d-2ea785a2485a
bundle-4839010336.5MBSDDC_MANAGER_VCF-4.3.1.0-18624509PATCH4162045d-0b25-4ca3-8e38-0371908ed9e6
bundle-48392230.5MBSDDC_MANAGER_VCF-4.3.1.0-18624509PATCH(Drift)8f26c34a-7488-4960-aaf7-276ba313846b
bundle-475035394.0MBVCENTER-7.0.2.00500-18455184PATCH47d01e0c-ae43-4f74-a57a-b8b3ecbe878b
bundle-475028501.4MBNSX_T_MANAGER-3.1.3.1.0-18504668INSTALL9e3175b7-57bc-49cf-8e22-c3885061b48a
bundle-475047383.3MBVCENTER-7.0.2.00500-18455184INSTALLc49b858d-ed29-48bb-9d13-403d96a3ece3
4.3.0.0bundle-43745390.1MBESX_HOST-7.0.2-17867351PATCH1625a9f9-a96b-4dda-98c6-58938fb29667
bundle-464667123.1MBNSX_T_MANAGER-3.1.3.0.0-18328989PATCH104298b4-bee8-4eae-9791-fc8ff5516f31
bundle-4700610331.2MBSDDC_MANAGER_VCF-4.3.0.0-18433963PATCH3f44edc1-6862-4d85-b646-a6bc24698c32
bundle-47008230.3MBSDDC_MANAGER_VCF-4.3.0.0-18433963PATCH(Drift)5c1a58d6-2e2d-45bf-960a-5d05b7fee2e3
bundle-464685394.4MBVCENTER-7.0.2.00400-18356314PATCH8d83266a-3b96-467c-8071-74617e10da05
bundle-464678568.5MBNSX_T_MANAGER-3.1.3.0.0-18328989INSTALLf14e528f-df76-447d-a235-93b069291f5c
bundle-464697383.7MBVCENTER-7.0.2.00400-18356314INSTALL3f560300-18e9-4d9b-bcf5-0b4688c7612b
4.2.1.0bundle-425156995.1MBNSX_T_MANAGER-3.1.2.0.0-17883596PATCHc6550bcc-9519-423f-b383-625774fed5a6
bundle-4290510142.7MBSDDC_MANAGER_VCF-4.2.1.0-18016307PATCHdf3c4a11-cca4-4cad-b776-35f2035633dd
bundle-42906209.3MBSDDC_MANAGER_VCF-4.2.1.0-18016307PATCH(Drift)a534958a-5af3-4728-bcfc-4196e813f6fe
bundle-425215114.4MBVCENTER-7.0.1.00301-17956102PATCH731433e4-122e-40a9-aaba-3ebc1be133d3
bundle-425198394.9MBNSX_T_MANAGER-3.1.2.0.0-17883596INSTALL5881bb39-180f-4563-b434-824d9aa10413
bundle-425227722.8MBVCENTER-7.0.1.00301-17956102INSTALL300a8dcd-c774-4c22-9ea0-b0f08d38e004
4.2.0.0bundle-37983369.0MBESX_HOST-7.0.1-17551050PATCHe7ee206d-069f-4982-8271-38e7970dcf9a
bundle-328107057.7MBNSX_T_MANAGER-3.1.0.0.0-17107167PATCHff249395-d58a-4d3d-8111-9237fe6a6a45
bundle-3797910070.0MBSDDC_MANAGER_VCF-4.2.0.0-17559673PATCH906c8d8f-c28d-4122-8720-43be7af2cbfd
bundle-37982209.3MBSDDC_MANAGER_VCF-4.2.0.0-17559673PATCH(Drift)e53edad7-26df-4282-8874-d1724e63ac5b
bundle-353215140.8MBVCENTER-7.0.1.00200-17327517PATCHa9938c7e-d30c-4ce9-adab-831f835e6c12
bundle-328118427.7MBNSX_T_MANAGER-3.1.0.0.0-17107167INSTALL1cce3a86-7292-4c91-b0db-20274f2c741d
bundle-353227749.3MBVCENTER-7.0.1.00200-17327517INSTALL9d272a97-9a55-492e-b661-0a8f3f2dfd4a

Source https://kb.vmware.com/s/article/96099

How to use: Downloading specific VCF bundles via CLI

Replacing the idps reporting Corfu certificate in NSX

In this blog we will go over replacing the idps reporting Corfu certificate in NSX Corfu certificate in NSX. In this example I will be using the UI to generate the self signed certificate and then an API call to replace the certificate.

In my case the cluster manager Corfu certificate has already expired

In the top menu bar I went to Generate -> Generate Self Signed Certificate

Next I had to grab the new certificate ID

The next step is to replace the old certificate with the new certificate via an API call. For this I used Postman but any other tool could potentially be used.

The URL for the post call would go against https://nsx-vip-01a.corp.local/api/v1/trust-management/certificates/cert_id?action=apply_certificate&service_type=CBM_IDPS_REPORTING&node_id=node_id

The node ID can be found under Appliances -> View details on node, the value to the right for UUID ex

For authentication I used basic, per best practices we should be using a token.

For headers had to add Content-Type application\json ex

In the body I picket raw and added the following in

{ "cert_id": "0cc2f4f0-f409-4849-bf01-cfe454349a12",
"service_type": "CBM_IDPS_REPORTING" }

The cert ID is from the certificate I generated earlier. ex

Once I clicked send I was presented back with a 200 OK

Going in the web browser I can also see that the new certificate is now used and the old one doesn’t have anything assigned to it ex

The final step I did was removing the old certificate by clicking on the 3 dots to left and picking delete from the menu

Replacing the cluster manager Corfu certificate in NSX

In this blog we will go over replacing the cluster manager Corfu certificate in NSX. In this example I will be using the UI to generate the self signed certificate and then an API call to replace the certificate.

In my case the cluster manager Corfu certificate has already expired

In the top menu bar I went to Generate -> Generate Self Signed Certificate

Next I had to grab the new certificate ID

The next step is to replace the old certificate with the new certificate via an API call. For this I used Postman but any other tool could potentially be used.

The URL for the post call would go against https://nsx-vip-01a.corp.local/api/v1/trust-management/certificates/cert_id?action=apply_certificate&service_type=CBM_CLUSTER_MANAGER&node_id=node_id

The node ID can be found under Appliances -> View details on node, the value to the right for UUID ex

For authentication I used basic, per best practices we should be using a token.

For headers had to add Content-Type application\json ex

In the body I picket raw and added the following in

{ "cert_id": "0d77eb4c-b305-41a1-b0c4-da7260191d6d",
"service_type": "CBM_CLUSTER_MANAGER" }

The cert ID is from the certificate I generated earlier. ex

Once I clicked send I was presented back with a 200 OK

Going in the web browser I can also see that the new certificate is now used and the old one doesn’t have anything assigned to it ex

The final step I did was removing the old certificate by clicking on the 3 dots to left and picking delete from the menu

Replacing the Monitoring Corfu certificate in NSX

In this blog we will go over replacing the Corfu certificate in NSX. In this example I will be using the UI to generate the self signed certificate and then an API call to replace the certificate.

In my case the Monitoring Corfu certificate has already expired

In the top menu bar I went to Generate -> Generate Self Signed Certificate

Next I had to grab the new certificate ID

The next step is to replace the old certificate with the new certificate via an API call. For this I used Postman but any other tool could potentially be used.

The URL for the post call would go against https://nsx-vip-01a.corp.local/api/v1/trust-management/certificates/cert_id?action=apply_certificate&service_type=CBM_MONITORING&node_id=node_id

The node ID can be found under Appliances -> View details on node, the value to the right for UUID ex

For authentication I used basic, per best practices we should be using a token.

For headers had to add Content-Type application\json ex

In the body I picket raw and added the following in

{ "cert_id": "de5aed8d-cc84-4d0b-b487-8b6be2a022ba",
"service_type": "CBM_MONITORING" }

The cert ID is from the certificate I generated earlier. ex

Once I clicked send I was presented back with a 200 OK

Going in the web browser I can also see that the new certificate is now used and the old one doesn’t have anything assigned to it ex

The final step I did was removing the old certificate by clicking on the 3 dots to left and picking delete from the menu

Replacing the CSM Corfu certificate in NSX

In this blog we will go over replacing the Corfu certificate in NSX. In this example I will be using the UI to generate the self signed certificate and then an API call to replace the certificate.

In my case the CSM Corfu certificate has already expired

In the top menu bar I went to Generate -> Generate Self Signed Certificate

Next I had to grab the new certificate ID

The next step is to replace the old certificate with the new certificate via an API call. For this I used Postman but any other tool could potentially be used.

The URL for the post call would go against https://nsx-vip-01a.corp.local/api/v1/trust-management/certificates/cert_id?action=apply_certificate&service_type=CBM_CSM&node_id=node_id

The node ID can be found under Appliances -> View details on node, the value to the right for UUID ex

For authentication I used basic, per best practices we should be using a token.

For headers had to add Content-Type application\json ex

In the body I picket raw and added the following in

{ "cert_id": "65f3c890-485c-4c54-b80a-51cef8db7124",
"service_type": "CBM_CSM" }

The cert ID is from the certificate I generated earlier. ex

Once I clicked send I was presented back with a 200 OK

Going in the web browser I can also see that the new certificate is now used and the old one doesn’t have anything assigned to it ex

The final step I did was removing the old certificate by clicking on the 3 dots to left and picking delete from the menu